4.5 Design of Analogue Filters

|

133

a bandwidthf = fD2fD1 of 20 Hz is to be designed using an RLC element. For this

purpose, the corresponding normalised low-pass filter from the previous example can

be used (cf. Equation 4.32) and then the low-pass-bandstop-transformation according

to Table 4.5 can be performed. This results in:

AnTP(P) =

1

P + 1 bzw. AnTP(j) =

1

j+ 1 .

(4.37)

If the frequencies are expressed in terms of angular frequencies, the associated fre-

quency transformation on denormalisation gives:

= −ωBω2

0/ωB

ωω2

0/ω

,

mit ωB = ωD1 und ω2

0

ωB

= ωD2 .

(4.38)

Substituting Equation 4.38 into Equation 4.37, it follows for the bandstop transfer

function:

ABS() =

ω2 ω2

0

ω2 ω2

0 (ωBω2

0/ωB)

⏟⏟⏟⏟⏟⏟⏟⏟⏟⏟⏟⏟⏟⏟⏟⏟⏟⏟⏟⏟⏟⏟⏟⏟⏟⏟⏟

ω

.

(4.39)

This transfer function must be identical to that of an RLC element, which is obtained

by applying the equation for a voltage divider (cf. Figure 4.41,left) it follows for

ARLC() = U2

U1

=

ω2 1/LC

ω2 1/LCjωR/L .

(4.40)

Since both transfer functions must be identical, it follows by comparison:

ABS() =

ω2 ω2

0

ω2 ω2

0 (ωBω2

0/ωB)

⏟⏟⏟⏟⏟⏟⏟⏟⏟⏟⏟⏟⏟⏟⏟⏟⏟⏟⏟⏟⏟⏟⏟⏟⏟⏟⏟

ω

= ARLC() =

ω2 1/LC

ω2 1/LCjωR/L

(4.41)

and hence:

ω2

0 = 1

LC

und

ω = R

L .

(4.42)

Because of the relationship ω2

0 = ωD1ωD2 = (2π50 Hz)2 and ωB.ω2

0/ωB =

ωD1ωD2 =ω = 2π20 Hz one obtains e.g. with capacitance choice of the capacitor C

of 100 μF:

L = ω2

0 C = 101.23 mH

R =ωL = 12.73 Ω.

(4.43)

The corresponding frequency response calculated with LTspice according to mag-

nitude and phase is shown in Figure 4.41 (right). The LTspice-simulation of a filtered

ECG signal, which was strongly disturbed by a 50 Hz mains hum signal, is shown in

Figure 4.42.